    Interface IOperatorParameters

    Index

    Properties

    calcPeriodDate: TUint8

    Start date of the monthly billing period.

    currentTransformationRatioDenominator: TUint16

    Denominator of the current transformation ratio.

    currentTransformationRatioNumerator: TUint16

    Numerator of the current transformation ratio.

    date: TUint8

    Date of parameters recording.

    Display settings for meter readings (first 32 screens).

    Display settings for meter readings.

    Display settings for meter readings.

    Display settings for meter readings.

    energyDecimalPoint: TUint8

    The number of digits after the decimal point for displaying energy values.

    Value Mode
    0x00 8+0
    0x01 7+1
    0x02 6+2
    0x03 5+3
    freqMax: TUint8

    Maximum threshold for the frequency of the grid voltage.

    freqMin: TUint8

    Minimum threshold for the frequency of the grid voltage.

    ipThreshold: TUint32

    Maximum current threshold, mA.

    month: TUint8

    Month of parameters recording.

    phMin: TUint16

    Minimum threshold for the cos φ value.

    pMaxDef: TUint8

    0 - PMAX = POWER_A + POWER_B + POWER_C; 1 - PMAX is the averaged power over the integration period.

    pmaxThreshold0: TUint32

    Maximum active power threshold for tariff T1, Watts.

    pmaxThreshold1: TUint32

    Maximum active power threshold for tariff T2, Watts.

    pmaxThreshold2: TUint32

    Maximum active power threshold for tariff T3, Watts.

    pmaxThreshold3: TUint32

    Maximum active power threshold for tariff T4, Watts.

    Relay settings.

    reserved: TUint8

    Reserved byte.

    rmaxThreshold0: TUint32

    Maximum reactive power threshold for tariff T1, VAR.

    rmaxThreshold1: TUint32

    Maximum reactive power threshold for tariff T2, VAR.

    rmaxThreshold2: TUint32

    Maximum reactive power threshold for tariff T3, VAR.

    rmaxThreshold3: TUint32

    Maximum reactive power threshold for tariff T4, VAR.

    Controls the data transmission speed for UART interfaces.

    ten: TUint8

    Integration period for energy profiles.

    15 - 15 minutes; 0, 30 - 30 minutes; 60 - 60 minutes.

    since build 0.0.17

    timeIntervalPowerOff: TUint8

    Interval for tracking power off events, in minutes.

    since build 0.0.17

    timeoutBadVAVB: TUint8

    Timeout for relay deactivation due to poor voltage, seconds.

    timeoutCos: TUint8

    Timeout for relay deactivation based on cos φ.

    timeoutDisplay: TUint8

    Display active time.

    timeoutIMax: TUint8

    Timeout for relay deactivation based on maximum current.

    timeoutPMax: TUint8

    Timeout for relay deactivation based on maximum power.

    timeoutScreen: TUint8

    Display active time for each screen.

    tint: TUint8

    Power averaging interval, in minutes (1-60).

    tu: TUint8

    Voltage averaging interval.

    0, 1, 3, 5, 10, 15, 30 minutes.

    since build 0.0.17

    Measurement type settings.

    voltageTransformationRatioDenominator: TUint16

    Denominator of the voltage transformation ratio.

    voltageTransformationRatioNumerator: TUint16

    Numerator of the voltage transformation ratio.

    vpThreshold: TUint32

    Maximum voltage threshold, mV.

    vThreshold: TUint32

    Minimum voltage threshold, mV.

    year: TUint8

    Year of parameters recording.