jooby-codec
    Preparing search index...

    Interface IDisplaySet1OperatorParameter

    interface IDisplaySet1OperatorParameter {
        ACTIVE_ENERGY_T1: boolean;
        ACTIVE_ENERGY_T2: boolean;
        ACTIVE_ENERGY_T3: boolean;
        ACTIVE_ENERGY_T4: boolean;
        EXPORTED_ACTIVE_ENERGY_T1: boolean;
        EXPORTED_ACTIVE_ENERGY_T2: boolean;
        EXPORTED_ACTIVE_ENERGY_T3: boolean;
        EXPORTED_ACTIVE_ENERGY_T4: boolean;
        EXPORTED_NEGATIVE_REACTIVE_ENERGY_T1: boolean;
        EXPORTED_NEGATIVE_REACTIVE_ENERGY_T2: boolean;
        EXPORTED_NEGATIVE_REACTIVE_ENERGY_T3: boolean;
        EXPORTED_NEGATIVE_REACTIVE_ENERGY_T4: boolean;
        EXPORTED_REACTIVE_ENERGY_T1: boolean;
        EXPORTED_REACTIVE_ENERGY_T2: boolean;
        EXPORTED_REACTIVE_ENERGY_T3: boolean;
        EXPORTED_REACTIVE_ENERGY_T4: boolean;
        NEGATIVE_REACTIVE_ENERGY_T1: boolean;
        NEGATIVE_REACTIVE_ENERGY_T2: boolean;
        NEGATIVE_REACTIVE_ENERGY_T3: boolean;
        NEGATIVE_REACTIVE_ENERGY_T4: boolean;
        REACTIVE_ENERGY_T1: boolean;
        REACTIVE_ENERGY_T2: boolean;
        REACTIVE_ENERGY_T3: boolean;
        REACTIVE_ENERGY_T4: boolean;
        SET_ALL_SEGMENT_DISPLAY: boolean;
        SOFTWARE_VERSION: boolean;
        TOTAL_ACTIVE_ENERGY: boolean;
        TOTAL_EXPORTED_ACTIVE_ENERGY: boolean;
        TOTAL_EXPORTED_NEGATIVE_REACTIVE_ENERGY: boolean;
        TOTAL_EXPORTED_REACTIVE_ENERGY: boolean;
        TOTAL_NEGATIVE_REACTIVE_ENERGY: boolean;
        TOTAL_REACTIVE_ENERGY: boolean;
    }
    Index

    Properties

    ACTIVE_ENERGY_T1: boolean

    Active energy (A+) for tariff T1 (1.8.1).

    ACTIVE_ENERGY_T2: boolean

    Active energy (A+) for tariff T2 (1.8.2).

    ACTIVE_ENERGY_T3: boolean

    Active energy (A+) for tariff T3 (1.8.3).

    ACTIVE_ENERGY_T4: boolean

    Active energy (A+) for tariff T4 (1.8.4).

    EXPORTED_ACTIVE_ENERGY_T1: boolean

    Exported active energy (A-) for tariff T1 (2.8.1 for G-type meters).

    EXPORTED_ACTIVE_ENERGY_T2: boolean

    Exported active energy (A-) for tariff T2 (2.8.2 for G-type meters).

    EXPORTED_ACTIVE_ENERGY_T3: boolean

    Exported active energy (A-) for tariff T3 (2.8.3 for G-type meters).

    EXPORTED_ACTIVE_ENERGY_T4: boolean

    Exported active energy (A-) for tariff T4 (2.8.4 for G-type meters).

    EXPORTED_NEGATIVE_REACTIVE_ENERGY_T1: boolean

    Exported negative reactive energy (A-R-) for tariff T1 (7.8.1 for G-type meters).

    EXPORTED_NEGATIVE_REACTIVE_ENERGY_T2: boolean

    Exported negative reactive energy (A-R-) for tariff T2 (7.8.2 for G-type meters).

    EXPORTED_NEGATIVE_REACTIVE_ENERGY_T3: boolean

    Exported negative reactive energy (A-R-) for tariff T3 (7.8.3 for G-type meters).

    EXPORTED_NEGATIVE_REACTIVE_ENERGY_T4: boolean

    Exported negative reactive energy (A-R-) for tariff T4 (7.8.4 for G-type meters).

    EXPORTED_REACTIVE_ENERGY_T1: boolean

    Exported reactive energy (A-R+) for tariff T1 (6.8.1 for G-type meters).

    EXPORTED_REACTIVE_ENERGY_T2: boolean

    Exported reactive energy (A-R+) for tariff T2 (6.8.2 for G-type meters).

    EXPORTED_REACTIVE_ENERGY_T3: boolean

    Exported reactive energy (A-R+) for tariff T3 (6.8.3 for G-type meters).

    EXPORTED_REACTIVE_ENERGY_T4: boolean

    Exported reactive energy (A-R+) for tariff T4 (6.8.4 for G-type meters).

    NEGATIVE_REACTIVE_ENERGY_T1: boolean

    Negative reactive energy (R-) for tariff T1 (4.8.1 for R-type meters), (A+R-, 8.8.1 for G-type meters).

    NEGATIVE_REACTIVE_ENERGY_T2: boolean

    Negative reactive energy (R-) for tariff T2 (4.8.2 for R-type meters), (A+R-, 8.8.2 for G-type meters).

    NEGATIVE_REACTIVE_ENERGY_T3: boolean

    Negative reactive energy (R-) for tariff T3 (4.8.3 for R-type meters), (A+R-, 8.8.3 for G-type meters).

    NEGATIVE_REACTIVE_ENERGY_T4: boolean

    Negative reactive energy (R-) for tariff T4 (4.8.4 for R-type meters), (A+R-, 8.8.4 for G-type meters).

    REACTIVE_ENERGY_T1: boolean

    Reactive energy (R+) for tariff T1 (3.8.1 for R-type meters), (A+R+, 5.8.1 for G-type meters).

    REACTIVE_ENERGY_T2: boolean

    Reactive energy (R+) for tariff T2 (3.8.2 for R-type meters), (A+R+, 5.8.2 for G-type meters).

    REACTIVE_ENERGY_T3: boolean

    Reactive energy (R+) for tariff T3 (3.8.3 for R-type meters), (A+R+, 5.8.3 for G-type meters).

    REACTIVE_ENERGY_T4: boolean

    Reactive energy (R+) for tariff T4 (3.8.4 for R-type meters), (A+R+, 5.8.4 for G-type meters).

    SET_ALL_SEGMENT_DISPLAY: boolean

    Test display.

    SOFTWARE_VERSION: boolean

    Display software version.

    TOTAL_ACTIVE_ENERGY: boolean

    Total active energy (A+) across all tariffs (1.8.0).

    TOTAL_EXPORTED_ACTIVE_ENERGY: boolean

    Total exported active energy (A-) across all tariffs (2.8.0 for G-type meters).

    TOTAL_EXPORTED_NEGATIVE_REACTIVE_ENERGY: boolean

    Total exported negative reactive energy (A-R-) across all tariffs (7.8.0 for G-type meters).

    TOTAL_EXPORTED_REACTIVE_ENERGY: boolean

    Total exported reactive energy (A-R+) across all tariffs (6.8.0 for G-type meters).

    TOTAL_NEGATIVE_REACTIVE_ENERGY: boolean

    Total negative reactive energy (R-) across all tariffs (4.8.0 for R-type meters), (A+R-, 8.8.0 for G-type meters).

    TOTAL_REACTIVE_ENERGY: boolean

    Total reactive energy (R+) across all tariffs (3.8.0 for R-type meters), (A+R+, 5.8.0 for G-type meters).