jooby-codec
    Preparing search index...

    Interface IRelaySetOperatorParameter

    interface IRelaySetOperatorParameter {
        RELAY_OFF_ACTIVE_POWER_TARIFF_1: boolean;
        RELAY_OFF_ACTIVE_POWER_TARIFF_2: boolean;
        RELAY_OFF_ACTIVE_POWER_TARIFF_3: boolean;
        RELAY_OFF_ACTIVE_POWER_TARIFF_4: boolean;
        RELAY_OFF_CENTER: boolean;
        RELAY_OFF_DIFF_CURRENT_BAD: boolean;
        RELAY_OFF_I_LIMIT: boolean;
        RELAY_OFF_PF_MIN: boolean;
        RELAY_OFF_REACTIVE_POWER_TARIFF_1: boolean;
        RELAY_OFF_REACTIVE_POWER_TARIFF_2: boolean;
        RELAY_OFF_REACTIVE_POWER_TARIFF_3: boolean;
        RELAY_OFF_REACTIVE_POWER_TARIFF_4: boolean;
        RELAY_OFF_SALDO: boolean;
        RELAY_OFF_SALDO_SOFT: boolean;
        RELAY_OFF_TARIFF_1: boolean;
        RELAY_OFF_TARIFF_2: boolean;
        RELAY_OFF_TARIFF_3: boolean;
        RELAY_OFF_TARIFF_4: boolean;
        RELAY_OFF_V_BAD: boolean;
        RELAY_OFF_Y: boolean;
        RELAY_ON_CENTER: boolean;
        RELAY_ON_PB: boolean;
        RELAY_ON_PF_MIN: boolean;
        RELAY_ON_SALDO: boolean;
        RELAY_ON_TARIFF_1: boolean;
        RELAY_ON_TARIFF_2: boolean;
        RELAY_ON_TARIFF_3: boolean;
        RELAY_ON_TARIFF_4: boolean;
        RELAY_ON_TIMEOUT: boolean;
        RELAY_ON_V_GOOD: boolean;
        RELAY_ON_Y: boolean;
    }
    Index

    Properties

    RELAY_OFF_ACTIVE_POWER_TARIFF_1: boolean

    Turn off on exceeding the power consumption limit for tariff T1.

    RELAY_OFF_ACTIVE_POWER_TARIFF_2: boolean

    Turn off on exceeding the power consumption limit for tariff T2.

    RELAY_OFF_ACTIVE_POWER_TARIFF_3: boolean

    Turn off on exceeding the power consumption limit for tariff T3.

    RELAY_OFF_ACTIVE_POWER_TARIFF_4: boolean

    Turn off on exceeding the power consumption limit for tariff T4.

    RELAY_OFF_CENTER: boolean

    Turn off by command from the center.

    RELAY_OFF_DIFF_CURRENT_BAD: boolean

    Turn off on exceeding the differential current limit.

    RELAY_OFF_I_LIMIT: boolean

    Turn off on load current exceeding.

    RELAY_OFF_PF_MIN: boolean

    Turn off on cos φ.

    RELAY_OFF_REACTIVE_POWER_TARIFF_1: boolean

    Turn off on exceeding the reactive power consumption limit for tariff T1.

    RELAY_OFF_REACTIVE_POWER_TARIFF_2: boolean

    Turn off on exceeding the reactive power consumption limit for tariff T2.

    RELAY_OFF_REACTIVE_POWER_TARIFF_3: boolean

    Turn off on exceeding the reactive power consumption limit for tariff T3.

    RELAY_OFF_REACTIVE_POWER_TARIFF_4: boolean

    Turn off on exceeding the reactive power consumption limit for tariff T4.

    RELAY_OFF_SALDO: boolean

    Turn off based on saldo.

    RELAY_OFF_SALDO_SOFT: boolean

    Turn off based on saldo with condition.

    RELAY_OFF_TARIFF_1: boolean

    Turn off by tariff T1.

    RELAY_OFF_TARIFF_2: boolean

    Turn off by tariff T2.

    RELAY_OFF_TARIFF_3: boolean

    Turn off by tariff T3.

    RELAY_OFF_TARIFF_4: boolean

    Turn off by tariff T4.

    RELAY_OFF_V_BAD: boolean

    Turn off on poor voltage.

    RELAY_OFF_Y: boolean

    Relay deactivation function.

    true - enabled, false - disabled.

    RELAY_ON_CENTER: boolean

    Turn on by command from the center.

    RELAY_ON_PB: boolean

    Turn on by button.

    RELAY_ON_PF_MIN: boolean

    Turn on when cos φ is normalized.

    RELAY_ON_SALDO: boolean

    Turn on based on saldo.

    RELAY_ON_TARIFF_1: boolean

    Turn on by tariff T1.

    RELAY_ON_TARIFF_2: boolean

    Turn on by tariff T2.

    RELAY_ON_TARIFF_3: boolean

    Turn on by tariff T3.

    RELAY_ON_TARIFF_4: boolean

    Turn on by tariff T4.

    RELAY_ON_TIMEOUT: boolean

    Turn on after timeout.

    RELAY_ON_V_GOOD: boolean

    Turn on by restoration of good voltage.

    RELAY_ON_Y: boolean

    Relay activation function.

    true - enabled, false - disabled.