jooby-codec
    Preparing search index...

    Interface IDisplaySet3OperatorParameter

    interface IDisplaySet3OperatorParameter {
        APPARENT_POWER_QMINUS_PHASE_C: boolean;
        MAX_ACTIVE_POWER_DAY_T2: boolean;
        MAX_ACTIVE_POWER_DAY_T3: boolean;
        MAX_ACTIVE_POWER_DAY_T4: boolean;
        MAX_ACTIVE_POWER_MONTH_T1: boolean;
        MAX_ACTIVE_POWER_MONTH_T2: boolean;
        MAX_ACTIVE_POWER_MONTH_T3: boolean;
        MAX_ACTIVE_POWER_MONTH_T4: boolean;
        MAX_DAY_ACTIVE_POWER_DAY_T1: boolean;
        MAX_EXPORTED_ACTIVE_POWER_DAY_T1: boolean;
        MAX_EXPORTED_ACTIVE_POWER_DAY_T2: boolean;
        MAX_EXPORTED_ACTIVE_POWER_DAY_T3: boolean;
        MAX_EXPORTED_ACTIVE_POWER_DAY_T4: boolean;
        MAX_EXPORTED_ACTIVE_POWER_MONTH_T1: boolean;
        MAX_EXPORTED_ACTIVE_POWER_MONTH_T2: boolean;
        MAX_EXPORTED_ACTIVE_POWER_MONTH_T3: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_DAY_T1: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_DAY_T2: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_DAY_T3: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_DAY_T4: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_MONTH_T1: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_MONTH_T2: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_MONTH_T3: boolean;
        MAX_NEGATIVE_REACTIVE_POWER_MONTH_T4: boolean;
        MAX_REACTIVE_POWER_DAY_T1: boolean;
        MAX_REACTIVE_POWER_DAY_T2: boolean;
        MAX_REACTIVE_POWER_DAY_T3: boolean;
        MAX_REACTIVE_POWER_DAY_T4: boolean;
        MAX_REACTIVE_POWER_MONTH_T1: boolean;
        MAX_REACTIVE_POWER_MONTH_T2: boolean;
        MAX_REACTIVE_POWER_MONTH_T3: boolean;
        MAX_REACTIVE_POWER_MONTH_T4: boolean;
    }
    Index

    Properties

    APPARENT_POWER_QMINUS_PHASE_C: boolean

    Apparent power S- of phase C, (quadrant QII + QIII) (70.7.0).

    MAX_ACTIVE_POWER_DAY_T2: boolean

    Maximum daily active power for tariff T2 (|P|, 15.26.2 for R-type meters), (P+, 1.26.2 for G-type meters).

    MAX_ACTIVE_POWER_DAY_T3: boolean

    Maximum daily active power for tariff T3 (|P|, 15.26.3 for R-type meters), (P+, 1.26.3 for G-type meters).

    MAX_ACTIVE_POWER_DAY_T4: boolean

    Maximum daily active power for tariff T4 (|P|, 15.26.4 for R-type meters), (P+, 1.26.4 for G-type meters).

    MAX_ACTIVE_POWER_MONTH_T1: boolean

    Maximum monthly active power for tariff T1 (|P|, 15.16.1 for R-type meters), (P+, 1.16.1 for G-type meters).

    MAX_ACTIVE_POWER_MONTH_T2: boolean

    Maximum monthly active power for tariff T2 (|P|, 15.16.2 for R-type meters), (P+, 1.16.2 for G-type meters).

    MAX_ACTIVE_POWER_MONTH_T3: boolean

    Maximum monthly active power for tariff T3 (|P|, 15.16.3 for R-type meters), (P+, 1.16.3 for G-type meters).

    MAX_ACTIVE_POWER_MONTH_T4: boolean

    Maximum monthly active power for tariff T4 (|P|, 15.16.4 for R-type meters), (P+, 1.16.4 for G-type meters).

    MAX_DAY_ACTIVE_POWER_DAY_T1: boolean

    Maximum daily active power for tariff T1 (|P|, 15.26.1 for R-type meters), (P+, 1.26.1 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_DAY_T1: boolean

    Maximum daily exported active power for tariff T1 (P-, 2.26.1 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_DAY_T2: boolean

    Maximum daily exported active power for tariff T2 (P-, 2.26.2 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_DAY_T3: boolean

    Maximum daily exported active power for tariff T3 (P-, 2.26.3 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_DAY_T4: boolean

    Maximum daily exported active power for tariff T4 (P-, 2.26.4 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_MONTH_T1: boolean

    Maximum monthly exported active power for tariff T1 (P-, 2.16.1 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_MONTH_T2: boolean

    Maximum monthly exported active power for tariff T2 (P-, 2.16.2 for G-type meters).

    MAX_EXPORTED_ACTIVE_POWER_MONTH_T3: boolean

    Maximum monthly exported active power for tariff T3 (P-, 2.16.3 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_DAY_T1: boolean

    Maximum daily negative reactive power for tariff T1 (Q-, 4.26.1 for R-type meters), (Q4, 8.26.1 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_DAY_T2: boolean

    Maximum daily negative reactive power for tariff T2 (Q-, 4.26.2 for R-type meters), (Q4, 8.26.2 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_DAY_T3: boolean

    Maximum daily negative reactive power for tariff T3 (Q-, 4.26.3 for R-type meters), (Q4, 8.26.3 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_DAY_T4: boolean

    Maximum daily negative reactive power for tariff T4 (Q-, 4.26.4 for R-type meters), (Q4, 8.26.4 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_MONTH_T1: boolean

    Maximum monthly negative reactive power for tariff T1 (Q-, 4.16.1 for R-type meters), (Q4, 8.16.1 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_MONTH_T2: boolean

    Maximum monthly negative reactive power for tariff T2 (Q-, 4.16.2 for R-type meters), (Q4, 8.16.2 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_MONTH_T3: boolean

    Maximum monthly negative reactive power for tariff T3 (Q-, 4.16.3 for R-type meters), (Q4, 8.16.3 for G-type meters).

    MAX_NEGATIVE_REACTIVE_POWER_MONTH_T4: boolean

    Maximum monthly negative reactive power for tariff T4 (Q-, 4.16.4 for R-type meters), (Q4, 8.16.4 for G-type meters).

    MAX_REACTIVE_POWER_DAY_T1: boolean

    Maximum daily reactive power for tariff T1 (Q+, 3.26.1 for R-type meters), (Q1, 5.26.1 for G-type meters).

    MAX_REACTIVE_POWER_DAY_T2: boolean

    Maximum daily reactive power for tariff T2 (Q+, 3.26.2 for R-type meters), (Q1, 5.26.2 for G-type meters).

    MAX_REACTIVE_POWER_DAY_T3: boolean

    Maximum daily reactive power for tariff T3 (Q+, 3.26.3 for R-type meters), (Q1, 5.26.3 for G-type meters).

    MAX_REACTIVE_POWER_DAY_T4: boolean

    Maximum daily reactive power for tariff T4 (Q+, 3.26.4 for R-type meters), (Q1, 5.26.4 for G-type meters).

    MAX_REACTIVE_POWER_MONTH_T1: boolean

    Maximum monthly reactive power for tariff T1 (Q+, 3.16.1 for R-type meters), (Q1, 5.16.1 for G-type meters).

    MAX_REACTIVE_POWER_MONTH_T2: boolean

    Maximum monthly reactive power for tariff T2 (Q+, 3.16.2 for R-type meters), (Q1, 5.16.2 for G-type meters).

    MAX_REACTIVE_POWER_MONTH_T3: boolean

    Maximum monthly reactive power for tariff T3 (Q+, 3.16.3 for R-type meters), (Q1, 5.16.3 for G-type meters).

    MAX_REACTIVE_POWER_MONTH_T4: boolean

    Maximum monthly reactive power for tariff T4 (Q+, 3.16.4 for R-type meters), (Q1, 5.16.4 for G-type meters).